MTBF in maintenance: meaning, formula and how to improve it

The filler failed twelve times last month. Is that bad? MTBF turns failures into a number you can compare. How to calculate it, why it isn't a lifetime, and how to raise it.

The filler on line 2 failed twelve times last month. Each time it was running again within an hour or two, and at the monthly review nobody can quite say whether twelve is bad, normal or better than before. Someone says it feels like more. Someone else says it was a bad batch of bottles.

MTBF settles that kind of argument. It turns those twelve failures into a number you can compare from month to month and from machine to machine.

MTBF, or mean time between failures, is the average operating time a repairable machine runs between one failure and the next. You calculate it as the total operating time in a period divided by the number of failures in that period. MTBF shows how often a machine fails, MTTR shows how long each failure lasts, and together they decide how available the machine is.

What does MTBF mean?

MTBF measures reliability: the higher it is, the longer a machine runs before it fails again. The word that matters is operating. Time a machine stands idle, waits for material or is stopped for planned maintenance doesn’t count.

MTBF applies to equipment that gets repaired and put back into service, such as a machine, a line or a pump. For parts that are replaced instead of repaired, such as a fuse or a sensor, the matching measure is MTTF, mean time to failure.

MTBF formula

MTBF = total operating time / number of failures

Use the same period and the same equipment for both numbers, and the same rules for what counts as a failure (more on that below).

How to calculate MTBF: an example

Take the filler. It ran 480 hours last month and failed 12 times.

  1. Total operating time: 480 hours.
  2. Number of failures: 12.
  3. MTBF = 480 / 12 = 40 hours.

For several identical machines, add up their operating hours and their failures before you divide. Four fillers that ran 480 hours each with 12, 9, 15 and 12 failures have an MTBF of 1,920 / 48 = 40 hours. Averaging the four machines’ own MTBFs (40, 53.3, 32 and 40 hours) gives 41.3 hours instead, because it weighs a machine that rarely failed the same as one that failed often.

Take the operating hours from the hour meter or the production records, not from the calendar. For the failures, NASA’s maintenance guide recommends the machine history stored in your CMMS (NASA).

What counts as a failure

MTBF only compares when everyone counts failures the same way. A failure is the loss of the machine’s ability to do its job, so planned stops aren’t failures, and a machine running a bit slower without missing any requirement hasn’t failed either. Decide the rest before you start, and write it down:

  • Which stops count: usually any unplanned stop where the machine can’t do its job and needs a repair. Planned stops, changeovers and waiting for material don’t count.
  • Minor stops: a jam the operator clears in a minute is a minor stop on most lines. Track minor stops separately, or they’ll swamp the real failures.
  • Repeat failures: a fault that comes back an hour after the repair is a second failure, and a sign the first repair missed the cause.

Be careful with small numbers. In an example from the NIST engineering statistics handbook, a system with 2 failures in 800 operating hours has an estimated MTBF of 400 hours, but the 90% confidence interval runs from 127 to 2,251 hours (NIST). One month of a reliable machine tells you very little. A year tells you more.

A single number also hides a trend. Plot cumulative failures against cumulative operating hours: a straight line means no trend, a line bending upward means failures are coming faster, and one bending downward means the machine is getting better (NIST).

MTBF is not a lifetime

If you’ve ever seen a power supply datasheet promise an MTBF of about 75 years, you’ve seen where the confusion starts. Rockwell’s 1606-XLE240E 24 V power supply lists an MTBF of 661,000 hours, about 75 years, and on the same page a minimum lifetime of 120,000 hours, about 14 years, both at 40 °C (Rockwell Automation). Nobody expects that power supply to outlive the plant. The MTBF describes random failures across many units during their useful life, and the lifetime is when parts such as the electrolytic capacitors wear out.

Datasheet figures assume a constant failure rate, so a unit that’s still running is as likely to fail in its tenth year as in its first. Under that assumption, as NASA’s guide puts it, “there is a 37 percent probability that a system will survive its mean life without failure” (NASA). Siemens shows what that means for a fleet: with an MTBF of 60 years, about 1.65% of units fail in the first year, around 330 out of 20,000 (Siemens).

100 identical units with an MTBF of 1,000 hours: how many run without a failure
  • Still running, no failure yet
  • Failed at least once

61 of 100 still run without a failure after 500 hours. 39 have already failed at least once.

37 of 100 still run without a failure after 1,000 hours. 63 have already failed at least once.

14 of 100 still run without a failure after 2,000 hours. 86 have already failed at least once.

Each square is one unit. The model assumes a constant failure rate, the assumption behind most datasheet MTBF figures: the chance of failing in the next hour is the same at any age.

The datasheet number also depends on how it was calculated. PULS rates its CP10.241 power supply at 661,000 hours under one calculation method, and at 213,000 or 47,000 hours under another, depending on where it’s installed (PULS). The US military handbook behind that second method warns that “a reliability prediction should never be assumed to represent the expected field reliability as measured by the user” (MIL-HDBK-217F, section 3.3). For the machines in your plant, the MTBF that counts is the one you measure from your own records.

Bearings, belts and seals are different again. They wear, so for some failure modes the chance of failing rises with age, and an average hides when that rise begins. NASA’s guide warns that MTBF “provides only the average age at which failure occurs, not the most likely age”. If you set replacement intervals, look at the spread of your own failure ages (a Weibull plot shows it), not the average. Where failures don’t rise with age, replacing the part on a schedule adds cost without making the machine more reliable.

MTBF vs MTTR vs MTTF

  • MTBF (mean time between failures): how long a repairable machine runs between failures.
  • MTTR (mean time to repair): how long it takes to get it running again after a failure.
  • MTTF (mean time to failure): how long a non-repairable part runs before it fails and gets replaced.
  • Failure rate: failures per hour of operation. With a constant rate, it’s 1 / MTBF.

Availability combines MTBF and MTTR:

availability = MTBF / (MTBF + MTTR)

A machine with an MTBF of 40 hours and an MTTR of 1.5 hours has an availability of 96.4%. Raise MTBF to 50 hours with the same MTTR and it goes up to 97.1%. That’s inherent availability: it only counts failures and the repairs after them. Planned stops and changeovers are left out, so it reads higher than the availability in your OEE report.

MTTR, MTBF and availability calculator*
MTTR 1.5 h 18 h / 12 repairs = 90 minutes
MTBF 40 h 480 h / 12 failures
Availability 96.4% 40 / (40 + 1.5)
  • Running, 480 h
  • Stopped, 12 times, 18 h

MTTR would be 1.1 h and availability 97.3%, with the same 12 failures.

* A simplified model. Real MTTR and availability figures take more inputs than these, such as when the clock starts and stops, which delays count, and planned downtime.

What is a good MTBF?

There’s no credible public benchmark, and we’d be suspicious of anyone who quotes one. MTBF depends on the machine, its duty, its age and how failures are counted, so a figure from another plant tells you little. Compare a machine with itself over time, compare identical machines across lines, and watch the trend after every change in maintenance.

How to improve MTBF

Start with the failures behind the number. If three of the filler’s twelve were the same fault, that’s your first root cause analysis. Then:

  • Remove the cause of repeat failures. NASA’s guide gives the classic case: “a bearing may fail repeatedly because of excessive bearing loads caused by an underlying misalignment problem”. Replacing the bearing only fixes the effect, and a root cause analysis finds the misalignment.
  • Balance and align precisely. In the same guide’s worked example, one ounce of imbalance at a 12-inch radius at 3,600 rpm adds about 275 pounds of force, which cuts the calculated life of bearings designed for a 1,000-pound rotor to less than half.
  • Run within design limits. Lower stress means fewer failures, and heat is a stress too. In one Phoenix Contact power supply’s datasheet, MTBF falls from over 1.9 million hours at 25 °C to over 486,000 hours at 60 °C (datasheet). That’s a good reason to fix the cabinet fan that stopped last summer.
  • Monitor the condition of parts that give a warning, such as bearings and gearboxes, and replace them in a planned stop before they fail. That’s predictive maintenance in its simplest form.
  • Cut maintenance that does more harm than good. NASA warns that “imposing an arbitrary preventive task often increases the average failure rate through the resetting of “infant mortality"". Every task that opens up a machine should have a reason, and our overview of the types of maintenance helps you pick the right one.
  • Change the design when the same part keeps failing for reasons maintenance can’t fix.

MTBF as a maintenance KPI

  • Report MTBF per machine or machine family every month, calculated over the last 12 months, next to MTTR.
  • Count failures from the CMMS or the maintenance journal, and check that every unplanned stop has a record.
  • Look at the failures behind the number. The most frequent causes usually explain most of the change.

Where Edmund fits

Raising MTBF starts with knowing why a machine failed before, and that knowledge is often scattered across journals, tickets and people’s memories. Edmund reads your maintenance journals and service records together with the PLC programs, electrical drawings and manuals, so a technician can ask whether the same fault happened before on this machine and what fixed it, and get the answer with its source. At Moravia Cans, the head of maintenance reports “a lower frequency of a specific failure, or even its complete elimination”. Faster diagnosis lowers MTTR at the same time: at Amcor Flexibles, repairs got 26% shorter. If one of your machines keeps failing the same way, send us the fault.

Frequently asked questions

What is MTBF in simple terms?

The average time a machine runs between one failure and the next.

How do you calculate MTBF?

Divide the total operating time in a period by the number of failures in the same period. 480 operating hours with 12 failures give an MTBF of 40 hours.

What is the difference between MTBF and MTTF?

MTBF is for equipment that gets repaired and put back into service. MTTF is for parts that are replaced when they fail.

Does a high MTBF mean a part will last that long?

No. MTBF is an average across many units. With a constant failure rate, only about 37% of units reach their MTBF without a failure, and wear-out can end a part’s life long before.

What is a good MTBF?

There’s no universal figure. Compare each machine with its own history and with identical machines, and aim for a rising trend.